Uploading FAI data to Net-Inspect: what to prepare.

Some aerospace customers ask suppliers to submit first articles through Net-Inspect instead of emailing a PDF. The data is the same AS9102 content, but it has to be structured, and the system is less forgiving than a person reading a PDF. Here's what to have ready.

Guide · 6 min read · Updated October 2026

Net-Inspect is a third-party platform, and each customer configures its own requirements in it. Treat this as a preparation checklist, and follow your customer's supplier instructions and the current guidance inside Net-Inspect for the exact steps. Toolrick isn't affiliated with Net-Inspect.

What Net-Inspect is, briefly

Net-Inspect is a web-based quality platform that aerospace manufacturers use to collect first article and other quality data from their supply chain. Instead of a PDF that someone reads, your FAI arrives as structured data: each characteristic, its requirement and its results in fields the customer can search, compare and review.

That's good for everyone once it works, but it means problems a person would shrug off, such as a tolerance typed as text or a characteristic number that doesn't match the drawing, can stop an upload or get it bounced back.

Before anything else: access

  • Get set up by your customer. Access is normally arranged through the customer that requires it. Ask your buyer or supplier quality engineer (SQE) who your contact is.
  • Know which parts need it. Customers often require Net-Inspect for some part numbers or programs and not others.
  • Read the customer's specific instructions. Many customers have their own rules on top of AS9102: required attachments, how to treat multiplied features, which designators to use.
  • Get the current import template from inside Net-Inspect if you plan to upload characteristic data from a spreadsheet rather than typing it in. Formats change; don't rely on a colleague's copy from two years ago.

Form 1 data

Have these exactly as they'll appear on the purchase order and drawing:

  • Part number, part name and part revision
  • Drawing number and drawing revision, plus any additional changes (ECNs, deviations) incorporated
  • Purchase order number and your supplier code for this customer
  • Serial number(s) of the FAI part(s)
  • Detail or assembly FAI; full or partial FAI, and for a partial FAI the baseline part number and revision and the reason
  • For assemblies, the sub-assembly and detail part numbers with their FAI report numbers

Form 2 data

  • Each material and special process, with its specification number and revision
  • The special process supplier and its supplier code, and whether it's on the customer's approved source list
  • Certificate of conformance numbers for material and processes
  • Functional test procedure numbers and acceptance report numbers, where applicable

Customers check special process sources closely. A heat treater or plater not on their approved list is a common reason for rejection, and it's far better to find that out before you upload.

Form 3 data

This is where structured data matters most:

  • Characteristic numbers that match the ballooned drawing exactly, including any sub-numbering for multiplied features.
  • Requirements split into parts. Structured systems often want nominal, upper and lower limits (or plus and minus tolerances) as separate numeric values, not one text string. Have both: the requirement as written on the drawing, and the numeric limits.
  • Units, consistently, especially on drawings that mix inch and metric.
  • Results as numbers for variable characteristics, and a clear accept/reject for attribute characteristics.
  • Characteristic designators (key, critical) using the customer's codes.
  • Nonconformance references for any characteristic that failed.
  • Reference locations (sheet and zone).

Attachments to gather

  • The ballooned drawing as a PDF, matching the drawing revision on Form 1
  • CMM reports and other raw measurement data
  • Material certifications and special process certifications
  • Test reports for functional testing
  • Any approved deviations or concessions

Check your customer's file size and file type limits, and name files so a reviewer can tell what they are without opening them.

Tips that prevent bounced submissions

  • Reconcile counts before uploading: balloons on the drawing, rows in your data, results per row.
  • Watch symbols. Ø, ±, ° and GD&T symbols can break in CSV files saved with the wrong encoding. Spot-check a few rows after import.
  • Don't round results to fewer decimal places than the tolerance needs.
  • Agree on multiplied features with your customer: one characteristic with several results, or one characteristic per instance.
  • Do a test submission on a simple part before a deadline-critical one.

Final check before you submit

  1. Part number, drawing number and both revisions match the purchase order and the ballooned PDF.
  2. Every balloon has a row, and every row has a result for every serial number in the FAI.
  3. Every failed characteristic references a nonconformance record.
  4. Every special process source is on the customer's approved list, with its certificate attached.
  5. For a partial FAI, the baseline and the reason are stated, and the scope covers everything the change could affect.
  6. Someone other than the preparer has reviewed the data, if your customer or your own procedure requires it.

How Toolrick helps

Toolrick keeps balloons, requirements, numeric limits and results together from the start, so the data is already structured when you need to submit it. The Pro plan exports a Net-Inspect-formatted CSV alongside the AS9102 PDF and Excel. Customer configurations differ, so run a test import with your first part and tell us if any column doesn't map; we'll adjust it.

It all starts with a ballooned drawing. Try the free AI ballooner on your next Net-Inspect part, and see AS9102 Form 3 explained for what each column means.

From the blog: Why FAI reports get rejected · First article inspection checklist · CoC vs material certs

Submit first articles without retyping them.

Balloon the drawing free, then export AS9102 and Net-Inspect data from one place with a 14-day trial.