How to read a CMM report: an annotated sample.

A CMM printout is dense, and every package lays it out a little differently. Underneath, they all say the same things. Here is a simplified sample report, read line by line, with the checks a senior inspector runs before any number goes onto Form 3.

The short answer
  • Read the CMM report header first: part number, revision, units, part temperature, probe and alignment. If any of those is wrong, every measured value below it is suspect.
  • Each CMM dimension line shows NOMINAL (the target), +TOL and -TOL (the tolerance band), MEAS (the measured value), DEV (measured minus nominal) and OUTTOL (how far outside tolerance, 0 when in tolerance).
  • True position on a CMM report is a diameter: 2 × √(dX² + dY²). With an Ⓜ modifier, the BONUS column adds the hole's departure from MMC to the allowed tolerance.
  • To fill AS9102 Form 3: match each CMM dimension to its balloon number and copy MEAS, not DEV, into field 9 (Results).

What does a CMM report look like?

A CMM report is a printout with a header (part, program, units, temperature, probe, alignment) followed by one block per dimension, each with nominal, tolerance, measured, deviation and out-of-tolerance columns. Below is a simplified, vendor-neutral sample. The column names follow the classic PC-DMIS text report, which many other packages resemble, but it isn't a copy of any one vendor's exact format. The part is a machined aluminum bracket with a Ø10 hole positioned to datums A, B and C.

SIMPLIFIED SAMPLE CMM REPORT
PART NO: 4471-102   REV: D   NAME: BRACKET, MOUNTING   S/N: 001
PROGRAM: 4471-102_D_OP20     RUN: 2026-10-27 09:42   OPERATOR: JM
UNITS = MM   PART TEMP: 20.4 C   TEMP COMP: ON (CTE 23.0 um/m/C)
PROBE: T1A0B0  TIP DIA 2.000  QUALIFIED 2026-10-27  STD DEV 0.0006
ALIGNMENT: ALN_ABC   LEVEL PLN_A / ROTATE PLN_B / ORIGIN A,B,C

DIM 5= DIAMETER OF CIRCLE CIR_H1                      (BALLOON 5)
AX    NOMINAL    +TOL    -TOL     MEAS      DEV    OUTTOL
D      10.000   0.050   0.000   10.032    0.032    0.000

DIM 6= POSITION OF CIRCLE CIR_H1  DIA 0.100 (M) |A|B|C| (BALLOON 6)
AX    NOMINAL    +TOL   BONUS     MEAS      DEV    OUTTOL
X      25.000                   25.031    0.031
Y      40.000                   39.962   -0.038
TP      0.000   0.100   0.032    0.098    0.098    0.000

DIM 7= DIAMETER OF CIRCLE CIR_BORE                    (BALLOON 9)
AX    NOMINAL    +TOL    -TOL     MEAS      DEV    OUTTOL
D      20.000   0.021   0.000   19.994   -0.006   0.006 <---

DIM 8= DISTANCE PLN_A TO PLN_TOP                      (BALLOON 3)
AX    NOMINAL    +TOL    -TOL     MEAS      DEV    OUTTOL
M      12.700   0.100   0.100   12.812    0.112   0.012 --->

DIM 9= FLATNESS OF PLN_A                              (BALLOON 1)
AX    NOMINAL    +TOL    -TOL     MEAS      DEV    OUTTOL
M       0.000   0.050   0.000    0.021    0.021    0.000

Real reports add graphics, bar charts and feature IDs. Strip those away and this is what's left. The balloon numbers in brackets are something good programmers add on purpose. If your reports don't have them, you'll be matching lines to balloons by hand, which is covered under Form 3 below.

Check six things in the header before reading any deviation: part number and revision, units, temperature, probe, alignment, and the date, program and operator. A report that passes every dimension but was run on the wrong revision is still a bad report.

  • Part number and revision. They must match the drawing and AS9102 Form 1. A program written for Rev C and run on a Rev D part is an easy error to miss, because nothing on the report looks wrong.
  • Units. UNITS = MM or IN. Check it against the drawing, not against your memory of the program.
  • Temperature. Dimensional specifications are defined at a standard reference temperature of 20 °C (ISO 1). Note the part temperature, whether temperature compensation was on, and which expansion coefficient (CTE) was used.
  • Probe. Tip diameter and when the tip was last qualified. A tip qualified last month on a different stylus build is a question mark.
  • Alignment. The features used to build the coordinate system. More on this below.
  • Date, program, operator. Traceability. The reviewer will want to tie the report to a specific serial number and run.

What do the columns on a CMM report mean?

The columns on a PC-DMIS-style CMM report are AX (axis), NOMINAL, +TOL, -TOL, BONUS (position lines only), MEAS, DEV and OUTTOL. Column names and sign conventions vary by package and by settings, so confirm them once for your own software.

ColumnWhat it meansWhat to watch
AXThe axis or quantity reported: X, Y, Z, D (diameter), R (radius), TP (true position), M (a generic measured value). Labels vary by package.A diameter reported as R (radius) will look half-size. Check before you copy.
NOMINALThe target value programmed from the model or drawing.It must equal the drawing nominal. If it doesn't, the program is out of date or was typed wrong.
+TOL / -TOLThe tolerance band. In our sample, -TOL is shown without a sign, so 12.700 +0.100 / -0.100 means 12.600 to 12.800.PC-DMIS shows -TOL without a minus sign unless the "Minus Tols Show Negative" option is on. Either way, confirm the limits match the drawing, including title-block tolerances.
BONUSExtra position tolerance from a material condition modifier (Ⓜ or Ⓛ), shown on position lines.Should be zero if the frame has no Ⓜ or Ⓛ.
MEASThe measured value. This is your result.MEAS, not DEV, goes on Form 3.
DEVMEAS minus NOMINAL.The sign tells you direction (see below).
OUTTOLHow far the reading is outside its tolerance limit. Zero when in tolerance.Any non-zero value is a nonconformance and needs an NCR reference on Form 3.

What do DEV and OUTTOL mean on a CMM report?

DEV is the measured value minus the nominal. OUTTOL is the distance from the measured value to the tolerance limit it broke, and it is 0 when the reading is in tolerance.

On a size line, a positive DEV means the feature is bigger than nominal. On a location line, a positive DEV means the feature sits further along the positive axis of the active alignment. So Y DEV -0.038 says the hole center sits 0.038 mm toward minus Y from where it should be.

OUTTOL compares the reading with the limit it crossed:

  • Dim 7, the bore: limits 20.000 to 20.021. Measured 19.994, which is 0.006 under the lower limit. OUTTOL reads 0.006, and the < arrow says the reading is low. The bore is undersize.
  • Dim 8, the height: limits 12.600 to 12.800. Measured 12.812, which is 0.012 over. OUTTOL reads 0.012. DEV (0.112) is not the amount out of tolerance. Only OUTTOL is.

Sign conventions differ between packages and settings. PC-DMIS prints OUTTOL as a positive number by default and marks low and high readings with < and > symbols. A settings switch makes OUTTOL carry the same sign as DEV. Other packages only color or flag the line. Learn your own package once, then trust the arrows.

The DEV sign tells the machinist what to fix. An undersize bore with a positive Y position error on every part points at the boring bar and the work offset. DEV signs across three or four parts are often more useful than any single pass or fail.

How do you read a true position line with MMC bonus?

Read the TP row: MEAS is the measured position (a diameter), +TOL is the stated tolerance, and BONUS is the extra tolerance the hole earns from its size. The part passes when MEAS is no more than +TOL plus BONUS. For Dim 6, position Ø0.100 at MMC to A, B and C:

  1. Radial offset: √(0.031² + 0.038²) = 0.049.
  2. True position (a diameter): 2 × 0.049 = 0.098.
  3. Bonus: the hole's maximum material condition (MMC) is its smallest allowed size, 10.000. Dim 5 measured 10.032, so, if that is the hole's actual mating size, the hole has departed 0.032 from MMC. Bonus = 0.032.
  4. Allowed: 0.100 + 0.032 = 0.132. Measured 0.098. Pass.

Without the Ⓜ, the allowed position would be 0.100 and the hole would still pass, with less margin. You can check any position line by hand with the true position calculator. For how bonus works on pins, and why a datum referenced at MMB is a different thing, see MMC bonus tolerance, with worked examples.

Check which size the bonus came from. Under ASME Y14.5, bonus at MMC comes from the feature's actual mating size: for a hole, the largest perfect pin (cylinder) that fits it. Many CMM programs report a least-squares diameter by default. For a hole, the least-squares diameter is normally larger than the mating size, so the bonus can come out larger than the hole really earns. Ask your programmer which fit was used for the size that feeds the bonus.

Got the drawing that goes with this report? Balloon it first, so every CMM line has a number to land on.

Try the free ballooner

What is the alignment section of a CMM report?

The alignment section shows how the CMM built the coordinate system that every X, Y and Z is measured in. On a good report the alignment reproduces the drawing's datum reference frame in the order the feature control frame gives.

For datums A, B and C, a typical alignment levels to the primary datum (A), rotates to the secondary (B), and takes the origin in each axis from the datum that controls that axis. Our sample reads LEVEL PLN_A / ROTATE PLN_B / ORIGIN A,B,C.

Things that should make you stop:

  • The alignment uses features that aren't datums on the drawing, such as a convenient machined face instead of datum B.
  • The datum order differs from the feature control frame. Swap B and C and the same part gives different position results.
  • Several alignments in one program, and a position call reported in the wrong one. Some packages print the active alignment name above each dimension. Check it.
  • A "best fit" alignment used for a GD&T evaluation with no reason written down. Best fit has uses in some profile and reverse-engineering work, but it isn't the drawing's datum reference frame.

How do you spot a bad CMM report?

A bad CMM report usually shows a pattern: every feature off by the same amount, or in the same direction. Shared errors like that point at the setup (probe, units, temperature, alignment), not at the part.

SymptomLikely causeCheck
Every hole reads small by about the tip diameter; every boss reads large by the same amountProbe radius compensation offProbe line in the header; re-measure one hole with a pin gauge
Every hole and boss is off by the same small amountWrong tip diameter applied, or a tip that needs requalifyingTip diameter and qualification date versus the stylus actually fitted
Nominals look 25.4 times too big or too small, or 12.700 where the drawing says .500Unit mismatch between program and drawingUNITS line versus the drawing title block
All lengths slightly long on a warm aluminum partPart not soaked to temperature, compensation offTemperature line. Aluminum grows about 0.014 mm per 100 mm at 6 °C above 20 °C
Position fails on every part in the same directionAlignment built on the wrong feature or wrong datum orderAlignment line versus the feature control frame
A nominal doesn't match the drawingProgram written to an older revisionProgram name and REV against Form 1
Fewer CMM dimensions than balloonsSome characteristics checked elsewhere (or missed)Every balloon needs a result from somewhere: CMM, hand gauge or visual
Position reported but no BONUS where the frame has ⓂModifier not set in the programFrame on the drawing versus the program's dimension call

The aluminum figure is simple arithmetic. Aluminum's expansion coefficient is about 23 µm per meter per °C, so 23 × 0.1 m × 6 °C ≈ 14 µm, or 0.014 mm. On a 100 mm length toleranced ±0.010, that is more than the whole plus side of the band. Steel, at about 11–12 µm/m/°C, grows roughly half as much: about 0.007 mm.

How do you transfer CMM results to AS9102 Form 3?

Match each CMM dimension to its balloon number, then copy the drawing requirement into Form 3 field 8 and the MEAS value into field 9. Form 3 is organized by balloon number, not by CMM dimension number, and the two rarely line up. In our sample, Dim 5 is balloon 5, but Dim 8 is balloon 3. The procedure:

  1. Balloon the drawing first, so the numbering is fixed before anyone writes a program. See how to balloon a drawing.
  2. Put the balloon number in each CMM dimension's name or comment. It costs the programmer a few seconds a feature and removes the matching step for the inspector.
  3. For each Form 3 row, find the matching CMM line and copy the requirement exactly as the drawing states it into field 8 (Requirement).
  4. Copy MEAS into field 9 (Results). For position, record the measured TP value, and note the bonus used if your customer wants it. Write 0.098 against Ø0.100 Ⓜ, not "OK".
  5. For any OUTTOL line, record the actual value anyway and put the NCR number in field 11 (Nonconformance Number).
  6. Reconcile the count. Every balloon must have a result. The ones the CMM didn't measure need a hand-gauge or visual result, with the gauge identified.
  7. Attach or reference the CMM report with its program name and run date, so the reviewer can trace the numbers.

The field numbers above (8 Requirement, 9 Results, 11 Nonconformance Number) are the same in AS9102 Rev B and Rev C. Rev C removed the Form 3 signature field and renumbered the comments column. Our Form 3 guide covers each column, and there's a free Form 3 Excel template. For what reviewers reject most often, see why FAI reports get rejected.

FAQ

What does OUTTOL mean on a CMM report?

OUTTOL is the amount by which a CMM measurement falls outside its tolerance limit. A value of 0 means the feature is in tolerance. A non-zero value is the distance past the limit that was broken, not the deviation from nominal. PC-DMIS prints OUTTOL as a positive number by default and marks low and high readings with arrows; some setups print it with the same sign as DEV.

Is DEV on a CMM report measured minus nominal?

Yes. On size and location lines, DEV is MEAS minus NOMINAL, so a positive DEV means the feature is larger than nominal or sits further along the positive axis of the active alignment. For true position, flatness and other geometric tolerances the nominal is 0, so DEV equals the measured value. DEV is not the amount out of tolerance; OUTTOL is.

Why is the measured true position bigger than the X and Y deviations?

True position is reported as the diameter of the zone the feature axis falls in, so it is twice the radial offset: 2 × √(dX² + dY²). For example, an X deviation of 0.031 and a Y deviation of -0.038 give a radial offset of 0.049 and a true position of 0.098. Comparing the radial offset with a diametral tolerance makes a part look twice as good as it is.

Can I attach the CMM printout instead of filling in Form 3?

Usually not on its own. Many customers accept a CMM report as supporting evidence, but they still expect AS9102 Form 3 to have a row and a recorded result for every ballooned characteristic, traceable by balloon number. Reference the CMM program name and run date on the FAI. Check your customer's FAI requirements before relying on a printout alone.

Where software helps

The slow part isn't reading the report. It's retyping it into Form 3 by balloon number without a slip. Toolrick takes pasted CMM text output in PC-DMIS, Calypso and MCOSMOS style layouts, lines readings up with balloons for you to confirm, and shows pass and fail on the drawing. Formats vary, so check the first few lines it matches. Start by ballooning a drawing with the free AI ballooner, no account needed.

Related: AS9102 Form 3 explained · True position calculator · MMC bonus tolerance · AS9102 Form 1 explained · Gage R&R study, worked example · GD&T profile of a surface

Sources

  1. Minus Tols Show Negative (report columns AX, NOM, +TOL, -TOL, MEAS, DEV, OUT-TOL), PC-DMIS 2023.1 Help, Hexagon
  2. UseNegativeOuttolBasedOnNegativeDeviation (OUTTOL sign setting), PC-DMIS 2022.1 Settings Editor, Hexagon
  3. Deviation Symbols, PC-DMIS 2023.1 Help, Hexagon
  4. ISO 1:2022, Geometrical product specifications (GPS): Standard reference temperature, ISO (catalog summary)
  5. Coefficients of Linear Thermal Expansion, The Engineering ToolBox
  6. GD&T Reference Chart (bonus tolerance, virtual condition), GD&T Basics
  7. AS9102 First Article Inspection Report: Rev B vs Rev C, Net-Inspect